| Availability: | |
|---|---|
| Quantity: | |
Product Description
Thermogravimetric Analyzer TGA
GC-TGA-101

Product Description:
TGA Analyzer (TG, TGA) is to observe the change of the mass of the sample with temperature or time during the process of heating and constant temperature, and the purpose is to study the thermal stability and composition of the material.
Widely used in research and development, process optimization and quality control in various fields such as plastics, rubber, coatings, pharmaceuticals, catalysts, inorganic materials, metal materials and composite materials.
Applications:
• Thermal Stability
• Decomposition Process
• Adsorption & Desorption
• Oxidation and Reduction
• Quantitative analysis of ingredients
• Effect of Additives and Fillers
• Moisture and volatiles
Structural advantage
1. The High - Performance TGA heating of the furnace body is made of custom-made nickel-chromium wire double-row winding, which reduces interference and is more resistant to high temperature.
2. The pallet sensor is made of alloy wire, which has the advantages of high temperature resistance, oxidation resistance and corrosion resistance.
3. The power supply and circulation cooling part are separated from the host to reduce the influence of heat and vibration on the microthermal balance.
4. Advanced TGA Equipment adopts the upper opening structure, which is easy to operate. It is difficult to move the furnace body up to place the sample, and it is easy to cause damage to the sample rod.
Controller, software advantages
1. Imported ARM processor is adopted, with faster sampling speed and faster processing speed.
2. Four-way sampling AD collects TG signal and temperature T signal.
3. Heating control, using PID algorithm, precise control. Multi-stage heating and constant temperature
4. USB two-way communication is used between the software and the instrument to fully realize remote operation. The parameter setting of the instrument and the operation of the instrument can be stopped through the computer software.
5. 7-inch full-color 24bit touch screen, better man-machine interface. TG calibration can be realized on the touch screen
Technical Parameters:
1. Temperature range: room temperature~1150℃
2. Temperature resolution: 0.01℃
3. Temperature fluctuation: ±0.01℃
4. Heating rate: 0.1~100℃/min
5. Temperature control method: heating, constant temperature
6. Program control: program setting multi-stage heating constant temperature
6. Balance measurement range: 0.01mg~3g, can be extended to 50g
7. Accuracy: 0.01mg
8. Constant temperature time: set arbitrarily
9. Display mode: large-screen LCD display of Chinese characters
10. Atmosphere device: Built-in gas flow meter, including two-way gas switching and flow control
11. Software: Intelligent software can automatically record TG curve for data processing and print experimental reports
12. Data interface: standard USB interface, dedicated software (software is free to upgrade from time to time)
13. Power supply: AC220V 50Hz
14. Appearance size: 500*400*430mm (length, width and height)
15. The software has a multi-point correction function, and the high and low temperature tests are more accurate
Test pattern:

Packing List
Name | Number |
Mainframe | 1 set |
Software | 1 set |
Power cable | 1 piece |
Data line | 1 piece |
Sample crucible | 100 |
10A fuse | 2 |
Manual | 1 instruction manual |
Warranty | 1 |
Certificate | 1 |
Trachea | 2 |
Tweezers, sample spoon | 1 set |
Our touch-screen melt flow rate tester measures thermoplastic MFR (0.1-150g/10min) with temp range 40-450℃. It has dual sensors, ±0.2℃ temp fluctuation, and auto/manual cutting. Compliant with GB/T3682, ISO 1133, it features a 7-inch touchscreen, real-time temp curves, and micro printer. The Hastelloy barrel resists corrosion, and 8 weights cover diverse tests. Suitable for plastic production, quality inspection, and labs optimizing processing parameters.
Our Semi-Automatic Melt Flow Index Tester (Model: GC-MI-DP) is designed to accurately measure the melt flow rate (MFR) of thermoplastics such as PC, nylon, and PP under controlled temperature and load conditions.
Featuring dual temperature control (RT–400 °C), imported sensors, and a Hastelloy alloy testing barrel, the instrument ensures reliable and repeatable results. It complies with key industry standards including GB/T3682-2018, ISO 1133, and ASTM D1238.
For enhanced operational efficiency, the tester supports electric loading/unloading and automatic specimen cutting. A touchscreen interface allows intuitive operation, while an integrated micro printer provides on-the-spot data output.
Ideal for plastic manufacturing, petrochemical facilities, and research laboratories, the GC-MI-DP is well-suited for high-throughput batch testing requiring precision and consistency.
This melt flow indexer tests MFR/MVR of plastic and rubber in viscous flow. It has a 304 stainless steel heating cylinder (RT-400℃, optional 500℃), dual sensors for temp precision, and 8 weight grades (0.325-21.6kg). Compliant with GB/T3682 and ASTM D1238, it resists corrosion from fluoroplastics. Key-stroke control simplifies operation, and a micro printer outputs data. Ideal for petrochemicals, plastic processing, and research institutes evaluating material processability.
This automatic melt flow index tester measures MFR/MVR of thermoplastics (high-temp PC, fluoroplastics) with auto-weight loading and cutting. It has multi-stage temp control (RT-450℃), dual platinum sensors, and an Omron encoder for precision. Compliant with GB/T3682, ISO 1133, it retains last test parameters and connects to computers via RS232. Features corrosion-resistant parts and fast temp recovery. Perfect for high-frequency testing in plastic factories, commodity inspection, and universities.
Our single-column universal testing machine (GC-WD-500D) is compact for tensile, compression, and bending tests on nonmetals (film, rubber, plastic). It has a 500kg load cell (±0.5% accuracy), speed range 0.01-500mm/min, and 800mm test stroke. Compliant with GB/T1041, ISO 178, it uses computer control for curve analysis and report generation. Features overcurrent/overload protection and emergency stop. Perfect for small labs, material inspection, and industries like textiles and household appliances.
This universal tensile testing machine (GC-WS-2000S) performs tensile, compression, bending, and shear tests on rubber, plastic, and metal. It has a 20KN high-precision sensor (±0.5% accuracy), AC servo motor, and Taiwan ball screw. Compliant with GB/T1040, ASTM D638, and ISO 527, it uses computer software for data analysis—auto-calculating tensile strength and elastic modulus. Safety features include overload shutdown and travel limits. Ideal for universities, research institutes, and auto/electronics industries.
This UV aging test chamber (GC-UV-A) uses ultraviolet lamps, condensation, and water spray to test material aging—fading, cracking, and embrittlement. It has UVA-340/UVB-313 lamp options, PID temperature control (RT+10~70℃), and ≥90% RH humidity. Compliant with GB/T16422.3, ISO 11507, and SAE J2020, it’s suitable for plastic, rubber, and fabric testing. The QTEST touchscreen enables program editing, and safety devices include over-temperature and water shortage protection. Ideal for quality control in automotive, textile, and coating industries.
Our UV accelerated aging chamber (GC-UV-A) rapidly simulates outdoor weathering—UV radiation, dew, and rain—for materials like plastic, coating, and rubber. Equipped with 8 UVA-340 lamps (315-400nm) and a Taiwan 7-inch touchscreen, it records irradiance, temperature, and time. Compliant with GB/T14552, ASTM D4329, and ISO 4892-3, it reproduces months of outdoor aging in days. Features independent radiation/condensation tests and real-time curve display. Perfect for material weatherability evaluation in manufacturing and research.
Plastic component manufacturing carries immense stakes on the factory floor. Subtle material variances often lead to catastrophic field failures later. These small deviations also cause frustrating processing bottlenecks during daily production.
Transit damage carries a brutally high price tag for modern manufacturers. It triggers widespread product loss, compromises brand integrity, and leads directly to harsh retailer chargebacks. Packaging engineers and quality assurance teams face a massive challenge trying to prevent these losses.
Selecting the wrong thermal analysis method brings high stakes to polymer characterization. You risk compliance failures, downstream product defects, and misallocated laboratory resources. Material scientists and quality managers must get this decision right to protect product integrity.
Material validation carries massive stakes in modern engineering. Standard ambient testing consistently fails to predict how materials behave in operational extremes. Aerospace components face brutal atmospheric re-entry temperatures.
Selecting the wrong testing method poses severe engineering risks. It yields inaccurate toughness data. You risk mischaracterizing polymer performance and inviting downstream product failures. Arbitrary testing protocols simply have no place in modern manufacturing.
Anomalous Melt Flow Index (MFI) results rarely point to an actual machine failure. They almost always trace back to a fundamental preparation failure before testing even begins. When operators load poorly prepared materials into a plastometer, inaccurate data inevitably trickles down the line.
Under-specifying a test chamber carries hidden risks. Inadequate cable routing or blocked airflow quickly invalidates critical test data. Such oversights inevitably delay vital product qualification schedules. At the procurement stage, teams usually prioritize standard chamber specifications.
Selecting the right melt flow testing standard goes far beyond a simple laboratory preference. It represents a critical supply chain and compliance decision for your manufacturing operation. Both major standards measure the ease of flow of melted plastics under specific thermal conditions.
Reliable product testing demands exact environmental replication to ensure valid, actionable results across every testing cycle. When you evaluate a component's endurance, you naturally expect your equipment to deliver absolute precision without question.
The mechanical reliability of interconnects dictates whether a larger system thrives or fails. Arbitrary force limits create massive blind spots for manufacturing teams. They lead to dual risks. High false-rejection rates frustrate quality assurance operators.
Polymer manufacturing demands absolute precision, making reliable melt flow rate (MFR) data essential for your daily quality control. Yet, inconsistent test results frequently disrupt otherwise smooth production workflows.
Choosing the wrong environmental stress test leads to two costly outcomes. You might let hidden defects escape into the field, causing catastrophic product failures. Alternatively, you might induce unrealistic laboratory failures. These false failures stall your entire production line needlessly.
Routine testing acts as your primary defense against severe compliance failures. You must never treat it as a simple bureaucratic checklist. Instead, view this process as essential protection against product liability and rejected material batches.
Selecting the right thermal testing or processing equipment requires balancing upfront capability against strict compliance and production requirements. Equipment engineers often face a challenging procurement decision. Both systems apply controlled thermal energy to a product.
Achieving precise test data requires more than just pushing a button on a sophisticated control panel. It depends heavily on how well your test samples interact within the physical workspace. Improper equipment sizing introduces costly operational risks for any testing laboratory.
Color inconsistency in plastics manufacturing creates heavy operational burdens for modern facilities. Batch rejections, brand compliance failures, and material waste quickly erode profit margins. Relying on subjective human visual inspection often yields unreliable results across different shifts.
When procuring a flame retardant test machine, buyers often focus strictly on thermocouple accuracy and heating elements.
Electrical component failures carry severe legal and operational stakes. Failing a compliance audit or experiencing a field failure due to inadequate flammability testing leads to massive product recalls.
Material flammability compliance operates as a strict binary. Polymer materials either pass UL 94 standards or fail. This result directly dictates market access and product safety liability.
Plastic component combustion creates severe liability for manufacturers in the electrical, automotive, and consumer electronics sectors. When a molded part fails during a fire event, it triggers immediate product recalls and invites heavy legal scrutiny.